Home » Project Material » Construction Of Automatic Water Level Controller For Both Overhead And Underground Tanks

Construction Of Automatic Water Level Controller For Both Overhead And Underground Tanks

5 Chapters
|
70 Pages
|
7,544 Words
|
Electrical Electronics Engineering

Complete Construction Of Automatic Water Level Controller For Both Overhead And Underground Tanks Project Materials (Chapters 1 to 5):

ABSTRACT

Automatic water level controller for both overhead and underground tank is designed to monitor the level of water in a tank. It displays the level of water and when it is at the lowest level; a pump is activated automatically to refill the tank. When the tank is filled to its maximum capacity, the pump is automatically de-energized. Several circuits are put together to ensure proper working of this design, and the block diagram includes the supply unit, the micro-processor unit, the sensor unit, the display unit and the pump drives unit. The power unit is responsible for turning on the entire circuit. Some components are used to set up power unit and they include; a 15v step down transformer, a bridge rectifier circuit, a smoothening capacitor and a voltage regulator IC. The microprocessor (AT89S50) controls virtually all the actions carried out in this design. (AT89S50) is used in the design. The sensor unit is responsible for sensing the level of water and transfer the current position of water to the microprocessor. The display unit in the circuit is use to physically show the current position of water in the tank, the properties of seven segment display are been used.

TABLE OF CONTENT

Cover Page
Title Page
Certification
Dedication
Abstract
Table Of Content
List Of Figure
List Of Table

 

CHAPTER ONE
1.0 INTRODUCTION

1.1 Backgrounds
1.2 Aims And Objective
1.3 Scope Of The Study
1.4 Constrains
1.5 Limitations Of The Project
1.6 Block Diagram
1.7 Project Report Organization

CHAPTER TWO
2.0 LITERATURE REVIEW

2.0 Review
2.1 Sensors

CHAPTER THREE
3.0 METHODOLOGY

3.0 Project Block Diagram
3.1 Fluid Level Detector
3.2 System Analysis
3.3 Step-Down Transformer
3.4 Transformer Circuit Representation
3.5 Diodes
3.6 Led
3.7 Bridge Rectifier
3.8 Voltage Regulators
3.9 Resistors
3.10 Transistors
3.11 Relays
3.12 Piezo Electric Buzzer
3.13 Hardware Component
3.14 Power Supply Unite
3.15 Display Unite
3.16 Input Interface Design
3.17 Pump Control Segment
3.18 Input Interface Design
3.19 Sensor Unit
3.20 Micro-Processor Unit

CHAPTER FOUR
4.1 OVERVIEW OF THE PROJECT

4.2 Software Design
4.3 Software Development
4.4 Translator
4.5 Linker/Loader
4.6 Debugging
4.7 Development Process
4.8 System Control Program Steps
4.9 Program

CHAPTER FIVE
5.0 SYSTEM TESTING AND IMPLIMENTATION

Test Plan And Test Data
5.0 Component Test
5.1 System Test
5.2 Transformer Test
5.3 Other Test
5.4 Experimented Value Vs. Actual Values
5.5 Performance Evaluation
5.6 Packaging
5.7 Bill Of Engineering Measurement And Evaluation
5.8 Conclusions
5.9 Problem Encountered
5.10 Recommendations
5.11 Reference

CHAPTER ONE

INTRODUCTION
1.0 BACKGROUND

The project “automatic water level control with an automatic pump control system” is design to monitor the level of liquid in the tank. The system has an automatic pumping system attached to it so as to refill the tank once the liquid gets to the lower threshold, while offing the pump once the liquid gets to the higher threshold. Sustainability of available water resource in many reason of the word is now a dominant issue. This problem is quietly related to poor water allocation, inefficient use, and lack of adequate and integrated water management. Water is commonly used for agriculture, industry, and domestic consumption. Therefore, efficient use and water monitoring are potential constraint for home or office water management system. Moreover, the common method of level control for home appliance is simply to start the feed pump at a low level and allow it to run until a higher water level is reached in the water tank. This water level control, controls monitor and maintain the water level in the overhead tank and ensures the continuous flow of water round the clock without the stress of going to switch the pump ON or OFF thereby saving time, energy, water, and
prevent the pump from overworking Besides this, liquid level control systems are widely used for monitoring of liquid levels in reservoirs, silos. Proper monitoring is needed to ensure water sustainability is actually being reached with disbursement linked to sensing and automation, such programmatic approach entails microcontroller based automated water level sensing and controlling or using 555 timer IC.

1.1 AIMS AND OBJECTIVES
The goal or objectives of which the designed device is expected to accomplish is to build an automatic water level control with automatic control system. In this project sensors are place at different level of the tank and with the aid of this sensors, the micro-controller monitor the level of the liquid at any particular point in time, some of the objectives are
1. to design an automatic water monitoring system
2. to incorporate an interactive medium between the end user and the machine
3. to prevent over labor of the pumping machine and prevent it from getting bad
4. to avoid wastage of water
5. since the demand of electricity is very high, automatic water level control saves energy

1.2 JUSTIFICATION
Automatic water level monitor came into existence because of human error and inconsistence that is associated with manually operated water pumping machine. This is because it takes time for individual who is manually operating the water pump to turn off the pumping machine and this may cause water spillage and at times the individual might not know that the water level has drop so low until the tank is completely empty. This was the problem that leads to the development of the ideal of an automatic water level control and automatic pump short down.

1.3 SCOPE OF THE PROJECT
The project was design to automatically control the pump which ensures constant reserve of water in the reservoir. The scope of the design was keep concise and simple to in other not to introduce unnecessary complexities and render it generally uncomfortable. The system does not have attached complex peripheral device which though impossible for the detail printable information has been excluded for reasons of affordability material of low range and less accurate performances as opposed to a
well built automatic water pump was use d to achieve this aim, the automatic water level controller detect and control the water in the tank

1.4 CONSTRAINS
The biggest setback experience during the course of this project is difficulties in finding the design of the project, secondly sourcing of material and component I used for the project were difficult to find like pump and buffer for programming

1.5 LIMITATIONS OF THE PROJECT
It is significant to know that this design is limited to 12v, 5amps electric pump and cannot be use to control industrial water pump above 5 amps
BLOCK DIAGRAM OVERVIEW
This project report writing is written is design in such a way that each chapter is related to the next as shown below
FIG 1.0 BLOCK DIAGRAM OF AUTOMATIC WATER LEVEL CONTROL WITH PUMP
POWER SUPPLY UNIT
CONTROL UNIT
DISPLAY UNIT
INPUT UNIT
CONTROL UNIT

1.6 PROJECT RESPORT ORGANISATION
The organization of this project report is well detailed and vast in its coverage it covers all the activities encountered during the research work. The first chapter of this work took care of the introduction, aims and objective, scope, Justification and project report organization. Chapter two highlight on literature review chapter three highlight on description of system and some of the component used were emphasized chapter four highlight on the system design and implementation, construction, testing and packaging of the pump. Chapter five is all about the conclusions problem encountered recommendation and cost of the project.

You Might Like These:
Project Structure

The introduction of Construction Of Automatic Water Level Controller For Both Overhead And Underground Tanks should start with the relevant background information of the study, clearly define the specific problem that it addresses, outline the main object, discuss the scope and any limitation that may affect the outcome of your findings

Literature Review of Construction Of Automatic Water Level Controller For Both Overhead And Underground Tanks should start with an overview of existing research, theoretical framework and identify any gaps in the existing literature and explain how it will address the gaps

Methodology of Construction Of Automatic Water Level Controller For Both Overhead And Underground Tanks should describe the overall design of your project, detail the methods and tools used to collect data explain the techniques used to analyse the collected data and discuss any ethical issues related to your project

Results should include presentation of findings and interpretation of results

The discussion section of Construction Of Automatic Water Level Controller For Both Overhead And Underground Tanks should Interpret the implications of your findings, address any limitations of your study and discuss the broader implications of your findings

The conclusion of Construction Of Automatic Water Level Controller For Both Overhead And Underground Tanks should include summarize the main results and conclusions of your project, provide recommendations based on your findings and offer any concluding remarks on the project.

References should List all the sources cited in Construction Of Automatic Water Level Controller For Both Overhead And Underground Tanks project by following the required citation style (e.g., APA, MLA, Chicago).

The appendices section should Include any additional materials that support your project (Construction Of Automatic Water Level Controller For Both Overhead And Underground Tanks) but are too detailed for the main chapters such as raw data, detailed calculations etc.