Home » Project Material » Design And Construction Of An Automatic Liquid Level Indicator With Alarm

Design And Construction Of An Automatic Liquid Level Indicator With Alarm

5 Chapters
|
61 Pages
|
8,506 Words
|
Construction Management/Technology

Complete Design And Construction Of An Automatic Liquid Level Indicator With Alarm Project Materials (Chapters 1 to 5):

ABSTRACT

This project is titled the design and construction of a liquid level sensor and alarm system. It is designed to indicate the level of liquid such as water in an over-head tank. It not only indicates the amount of water present in the overhead tank but also gives an alarm when the tank is full.

When the liquid is empty the wires in the tank are open circuited and the 180K resistors pulls the switch low hence opening the switch and LEDs are OFF. As the water starts filling up, first the wire in the tank connected to S1 and the + supply are shorted by water. This closes the switch S1 and turns the LED1 ON. As the water continues to fill the tank, the LEDs2 , 3 and 4 light up gradually.

When the liquid is full, the base of the transistor BC148 is pulled high by the liquid and this saturates the transistor, turning the buzzer ON. The SPST switch has to be opened to turn the buzzer OFF.

TABLE OF CONTENT

TABLE OF CONTENT
TITLE PAGE
APPROVAL PAGE
DEDICATION
ACKNOWLEDGEMENT
ABSTRACT
TABLE OF CONTENT

CHAPTER ONE
1.0 INTRODUCTION
1.1 BACKGROUND OF THE STUDY
1.2 PROBLEM STATEMENT
1.3 AIM / OBJECTIVE OF THE STUDY
1.4 SIGNIFICANCE OF THE PROJECT
1.5 SCOPE OF THE PROJECT

CHAPTER TWO
2.0 LITERATURE REVIEW
2.1 REVIEW OF RELATED THEORIES
2.2 REVIEW OF RELATED STUDIES
2.3 RESEARCH GAP
2.4 CONCLUSION

CHAPTER THREE
3.0 CONSTRUCTIONS
3.1 CIRCUIT DIAGRAM
3.2 CIRCUIT DESCRIPTION
3.3 CIRCUIT OPERATION
3.4 COMPONENTS USED
3.5 THE WORKING PRINCIPLE
3.5 POWER SUPPLY UNIT
3.6 POWER SUPPLY UNIT
3.7 SPECIFICATION AND OPERATION OF SYSTEM COMPONENT

CHAPTER FOUR
4.0 CONSTRUCTIONS
CIRCUIT OPERATION
CIRCUIT DIAGRAM
COMPONENTS REQUIREMENT
WORKING OF AUTOMATIC WATER LEVEL CONTROLLER
COMPONENTS PIN-OUT
POWER SUPPLY UNIT
POWER SUPPLY COMPONENTS5.1 INSTALLATION OF THE COMPLETE DESIGN
CONSTRUCTION PROCEDURE AND TESTING
CASING AND PACKAGING
ASSEMBLING OF SECTION
TESTING OF SYSTEM OPERATION
PROBLEMS ENCOUNTERED
COST ANALYSIS
DESCRIPTION OF COMPONENTS USED

CHAPTER SIX
5.1 CONCLUSION
5.2 RECOMMENDATION
REFERENCES

CHAPTER ONE

1.0 INTRODUCTION
1.1 Background of the study
The liquid level sensor is a device that measures the liquid level in a fixed container that is too high or too low. The level sensor is a device designed to monitor and measure liquid (and sometimes solid) levels. When the liquid level is detected, the sensor converts the sensed data into an electrical signal. Level sensors are mainly used for monitoring reservoirs, oil tanks or rivers (Henry, 2018).
According to the method of measuring the liquid level, it can be divided into two types: contact type and non-contact type. The input type water level transmitter we call is a contact measurement, which converts the height of the liquid level into an electrical signal for output. It is currently a widely used water level transmitter.
This device consists of 4 LED’s used to indicate ¼, ½, ¾, full levels. Basically the unit is made up of various sensors acting as a switch. This device came to mitigate problems such as poor water allocation, inefficient use, and lack of adequate and integrated water management. Automatic liquid level indicator system is designed to monitor liquid level in an overhead tank. This device helps the user to be aware of the water level in the tank through indicators. It is very useful because the user need not worry about the liquid such as water content during the peak hours of the day. It not only helps in the daily chores but also prevents water wastage. It reduces human labour, saves time and also keeps the user updated regarding the water content (Henry, 2018).

1.2 Statement of the problem
Nowadays, all the householders/owners are storing the water in overhead tanks by using the pumps. When the water is stored in the tank, no one can identify the level of water and also, no one can know when the water tank will fill. Hence there is an overflow of water in the tank, thus there is wastage of energy and water. To resolve this type of problems a water level indicator is built to indicate the level of liquid such as water in the overhead tanks.

1.3 Aim and objectives of the study
This work is aimed at building a liquid level indicator that will use four sensors to detect and indicate the four level of liquid in a container.
The objectives of the work are:
i. To build the system prototype at low cost
ii. To learn the working of a liquid indicator
iii. To automatically detect liquid level (1/4, ½, ¾ and full) with high precision.
iv. To control the supply of liquid thereby saving liquid.

1.4 Significance of the study
This study will bring solution to an overflowing of liquid from a container thereby preventing water wastage and saves electric energy. With this study, one can identify the level of liquid in a container. This study will also serve as a means of enlightening students on how to build simple electronics circuits.

1.5 Scope of the study
The scope of this work covers building a liquid level indicator using CD4066 CMOS IC as the heart of the circuit. The circuit consisting of 4 LED’s used to indicate ¼, ½, ¾ and full levels. When the liquid is full, the base of the transistor BC148 is pulled high by the liquid and this saturates the transistor, turning the buzzer ON thereby informing the user that the container is filled.

You Might Like These:
Project Structure

The introduction of Design And Construction Of An Automatic Liquid Level Indicator With Alarm should start with the relevant background information of the study, clearly define the specific problem that it addresses, outline the main object, discuss the scope and any limitation that may affect the outcome of your findings

Literature Review of Design And Construction Of An Automatic Liquid Level Indicator With Alarm should start with an overview of existing research, theoretical framework and identify any gaps in the existing literature and explain how it will address the gaps

Methodology of Design And Construction Of An Automatic Liquid Level Indicator With Alarm should describe the overall design of your project, detail the methods and tools used to collect data explain the techniques used to analyse the collected data and discuss any ethical issues related to your project

Results should include presentation of findings and interpretation of results

The discussion section of Design And Construction Of An Automatic Liquid Level Indicator With Alarm should Interpret the implications of your findings, address any limitations of your study and discuss the broader implications of your findings

The conclusion of Design And Construction Of An Automatic Liquid Level Indicator With Alarm should include summarize the main results and conclusions of your project, provide recommendations based on your findings and offer any concluding remarks on the project.

References should List all the sources cited in Design And Construction Of An Automatic Liquid Level Indicator With Alarm project by following the required citation style (e.g., APA, MLA, Chicago).

The appendices section should Include any additional materials that support your project (Design And Construction Of An Automatic Liquid Level Indicator With Alarm) but are too detailed for the main chapters such as raw data, detailed calculations etc.