Home » Project Material » Design And Construction Of A Geyser Timer

Design And Construction Of A Geyser Timer

ELECTRICAL ELECTRONICS ENGINEERING

INSTRUCTIONS:

  • You are perusing the project material titled “Design And Construction Of A Geyser Timer.”
  • The project material on Design And Construction Of A Geyser Timer is available for instant download.
  • Preview Chapter One of Design And Construction Of A Geyser Timer at no cost.
  • To access the complete project material for Design And Construction Of A Geyser Timer, kindly make a donation to support the ongoing maintenance and operation of this website.
  • The provided work on Design And Construction Of A Geyser Timer is intended solely for academic research purposes and should be utilized strictly as a set of guidelines.
  • Our objective in distributing Design And Construction Of A Geyser Timer is to aid individuals unfamiliar with project research, specifically writers seeking assistance in this area.
  • Kindly refrain from directly replicating the content provided in Design And Construction Of A Geyser Timer materials.
  • Feel free to reference “Design And Construction Of A Geyser Timer” in your work, provided that you paraphrase appropriately.
  • Unauthorized reproduction of Design And Construction Of A Geyser Timer content is prohibited under our Terms of Use.
  • UniProjects assumes no responsibility if you replicate the content of this Design And Construction Of A Geyser Timer.

This geyser timer circuit sounds an alarm after the set timing of 22 minutes when the water is heated up and can be used. The circuit comprises a timer IC 555 wired as an astable multivibrator with adjustable time period of 15 seconds. The astable output after inversion by an inverter drives decade counters IC3 and IC4 (each IC 7490) connected in cascade. The decade counters output is connected to decoders IC5 and IC6 (each IC 7442), respectively. The decoder outputs (Q8 outputs of IC5 and IC6) are fed to inverters and the inverter outputs, in turn, are fed to an AND gate. The AND output is connected to the reset pin of the astable multivibrator built around another timer IC 555 to sound the alarm.

TABLE OF CONTENTS

COVER PAGE

TITLE PAGE

APPROVAL PAGE

DEDICATION

ACKNOWELDGEMENT

ABSTRACT

CHAPTER ONE

1.0      INTRODUCTION

1.1      BACKGROUND OF THE PROJECT

  • PURPOSE OF THE PROJECT
  • AIM OF THE PROJECT
  • OBJECTIVE OF THE PROJECT
  • PURPOSE OF THE PROJECT
  • LIMITATION OF THE PROJECT
  • ADVANTAGES OF THE PROJECT
  • PROBLEM OF THE PROJECT
  • APPLICATION OF THE PROJECT
  • RESEARCH QUESTION
  • PROJECT ORGANISATION

CHAPTER TWO

LITERATURE REVIEW

  • OVERVIEW OF THE STUDY
  • REVIEW OF THE RELATED STUDY

 

CHAPTER THREE

3.0     CONSTRUCTION METHODOLOGY

3.1      BASIC OF THE SYSTEM

3.2     BLOCK DIAGRAM OF THE SYSTEM

3.3      SYSTEM OPERATION

3.4      CIRCUIT DIAGRAM

3.5      CIRCUIT DESCRIPTION

3.6     DESCRIPTION OF COMPONENTS USED

3.7      POWER SUPPLY UNIT

CHAPTER FOUR

4.0      TESTING AND RESULTS

  • CONSTRUCTION PROCEDURE AND TESTING
  • INSTALLATION OF THE COMPLET DESIGN
  • ASSEMBLING OF SECTIONS
  • TESTING OF SYSTEM OPERATION
  • COST ANALYSIS

CHAPTER FIVE

  • CONCLUSION
  • RECOMMENDATION
  • REFERENCES

 

KEYWORD: geyser timer, geyser circuit diagram, timer circuits, electric geyser wiring diagram, how to use geyser, geyser connection diagram, 555 timer projects, timer circuit using 555, advanced 555 timer projects.

Geyser timer circuit

The circuit comprises a timer IC 555 wired as an astable multivibrator with adjustable time period of 15 seconds. The astable output after inversion by an inverter drives decade counters IC3 and IC4 (each IC 7490) connected in cascade. The decade counters output is connected to decoders IC5 and IC6 (each IC 7442), respectively. The decoder outputs (Q8 outputs of IC5 and IC6) are fed to inverters and the inverter outputs, in turn, are fed to an AND gate. The AND output is connected to the reset pin of the astable multivibrator built around another timer IC 555 to sound the alarm. Now you can turn off the geyser.

A green LED (LED1) has been used as the power supply indicator.

Switch on the timer and the geyser at the same time. When the alarm sounds, it means that the water in the geyser has heated up and can be used.

Geyser timer circuit

Construction & testing

Advertisement

You can assemble the timer circuit on a general-purpose PCB and install it near your bathroom so that both the timer circuit and the geyser can be switched on simultaneously.

After the siren sounds, if required, we can increase the time by another 22 minutes for geyser by resetting the circuit by pushing reset switches S1 and S2 momentarily.

If you want to change the preset time of the geyser, the same can be easily done by combining appropriate outputs of IC5 and IC6 using DIP switches (S3 and S4) while keeping in mind IC5 outputs (Q0 through Q9) are spaced 15 seconds apart and IC6 outputs are spaced 150 seconds (2.5 minutes) apart.

Caution

Please note that the timer circuit has no connection with the geyser circuit. The geyser works off 220V AC, while the timer works off 5V DC.

Frequently Asked Questions

If you’re referencing specific information, quotes, or ideas from “Design And Construction Of A Geyser Timer”, provide a citation in the appropriate format such as APA, MLA, or Chicago.

The title page of downloaded document contains information about the author, editor, and publisher of Design And Construction Of A Geyser Timer material.

Select “Donate & Download,” on top of “Design And Construction Of A Geyser Timer” and upon completing your donation, you will be directed to the download page or you can chat with us for alternative donation methods.

You have the opportunity to upload content similar to “Design And Construction Of A Geyser Timer” and receive payment for each download of the material. Engage in a conversation with our representative if you have any topics related to Design And Construction Of A Geyser Timer.