Home » Project Material » Design And Construction Of A Power Supply Reversal Correcter Cum Preventer

Design And Construction Of A Power Supply Reversal Correcter Cum Preventer

ELECTRICAL ELECTRONICS ENGINEERING

INSTRUCTIONS:

  • You are perusing the project material titled “Design And Construction Of A Power Supply Reversal Correcter Cum Preventer.”
  • The project material on Design And Construction Of A Power Supply Reversal Correcter Cum Preventer is available for instant download.
  • Preview Chapter One of Design And Construction Of A Power Supply Reversal Correcter Cum Preventer at no cost.
  • To access the complete project material for Design And Construction Of A Power Supply Reversal Correcter Cum Preventer, kindly make a donation to support the ongoing maintenance and operation of this website.
  • The provided work on Design And Construction Of A Power Supply Reversal Correcter Cum Preventer is intended solely for academic research purposes and should be utilized strictly as a set of guidelines.
  • Our objective in distributing Design And Construction Of A Power Supply Reversal Correcter Cum Preventer is to aid individuals unfamiliar with project research, specifically writers seeking assistance in this area.
  • Kindly refrain from directly replicating the content provided in Design And Construction Of A Power Supply Reversal Correcter Cum Preventer materials.
  • Feel free to reference “Design And Construction Of A Power Supply Reversal Correcter Cum Preventer” in your work, provided that you paraphrase appropriately.
  • Unauthorized reproduction of Design And Construction Of A Power Supply Reversal Correcter Cum Preventer content is prohibited under our Terms of Use.
  • UniProjects assumes no responsibility if you replicate the content of this Design And Construction Of A Power Supply Reversal Correcter Cum Preventer.

ABSTRACT

When power-supply polarities of an electronic device are accidentally interchanged, the device runs the risk of damage. The danger can be avoided by adding this tiny circuit to the power supply section of the device. This power supply reversal correcter circuit will instantly correct the interchanged poles of the power supply and warn of the error by raising an alarm accompanied with a visual indication.

The control element is nothing but a relay (RL1). Its supply is made unidirectional by a series-connected diode (D1). Thus in normal state the relay is idle. This arrangement is connected in reverse across the power-supply output. The output of the add-on circuit, which is taken through the normally closed contacts of the relay, via fuse F1, supplies power to the load. This way, unwanted loading of the power supply by the relay is avoided. The normally closed (N/C) contacts of relay RL1 are connected to the input terminals of the power supply in the required polarity, while the normally open (N/O) contacts are connected to the reverse-polarity terminals.

TABLE OF CONTENTS

COVER PAGE

TITLE PAGE

APPROVAL PAGE

DEDICATION

ACKNOWELDGEMENT

ABSTRACT

CHAPTER ONE

1.0      INTRODUCTION

1.1      BACKGROUND OF THE PROJECT

  • PURPOSE OF THE PROJECT
  • AIM OF THE PROJECT
  • OBJECTIVE OF THE PROJECT
  • PURPOSE OF THE PROJECT
  • LIMITATION OF THE PROJECT
  • ADVANTAGES OF THE PROJECT
  • PROBLEM OF THE PROJECT
  • APPLICATION OF THE PROJECT
  • RESEARCH QUESTION
  • PROJECT ORGANISATION

CHAPTER TWO

LITERATURE REVIEW

  • OVERVIEW OF THE STUDY
  • REVIEW OF THE RELATED STUDY

CHAPTER THREE

3.0     CONSTRUCTION METHODOLOGY

3.1      BASIC OF THE SYSTEM

3.2      BLOCK DIAGRAM OF THE SYSTEM

3.3      SYSTEM OPERATION

3.4      CIRCUIT DIAGRAM

3.5      CIRCUIT DESCRIPTION

3.6     DESCRIPTION OF COMPONENTS USED

3.7      POWER SUPPLY UNIT

CHAPTER FOUR

4.0      TESTING AND RESULTS

  • CONSTRUCTION PROCEDURE AND TESTING
  • INSTALLATION OF THE COMPLET DESIGN
  • ASSEMBLING OF SECTIONS
  • TESTING OF SYSTEM OPERATION
  • COST ANALYSIS

CHAPTER FIVE

  • CONCLUSION
  • RECOMMENDATION
  • REFERENCES
Frequently Asked Questions

If you’re referencing specific information, quotes, or ideas from “Design And Construction Of A Power Supply Reversal Correcter Cum Preventer”, provide a citation in the appropriate format such as APA, MLA, or Chicago.

The title page of downloaded document contains information about the author, editor, and publisher of Design And Construction Of A Power Supply Reversal Correcter Cum Preventer material.

Select “Donate & Download,” on top of “Design And Construction Of A Power Supply Reversal Correcter Cum Preventer” and upon completing your donation, you will be directed to the download page or you can chat with us for alternative donation methods.

You have the opportunity to upload content similar to “Design And Construction Of A Power Supply Reversal Correcter Cum Preventer” and receive payment for each download of the material. Engage in a conversation with our representative if you have any topics related to Design And Construction Of A Power Supply Reversal Correcter Cum Preventer.